Intrinsically Safe Barrier PR Electronics 9202B1A
Skip to product information
1 of 1

  • GO Industrial Intrinsically Safe Barrier 9202B1A barrier datasheet IECEx Certificate of Conformity
  • GO Industrial Intrinsically Safe Barrier 9202B1A barrier datasheet
  • GO Industrial Intrinsically Safe Barrier 9202B1A barrier manual
  • Can be mounted in the safe area or in zone 2 / Cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Div. 1, Gr. A-G
  • Designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508
  • Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail
  • Front LED indicates operation status and malfunction
  • 2.6 kVac galvanic isolation between input, output and supply
  • Can be supplied separately or installed on power rail, PR type 9400
  • DIN rail mounting

Intrinsically Safe Barrier PR Electronics 9202B1A

SKU: 9202B1A

Intrinsically Safe Barrier PR Electronics 9202B1A

Regular price $449.00 AUD
Sale price $449.00 AUD Regular price
Save $0
Sold out
Inclusive of GST. Shipping calculated at checkout.

Other payment options

The Basics

    Overview

    The PR Electronics 9202B intrinsically safe barrier is an Ex pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in the hazardous area.

    Ex pulse isolator as a interface for NAMUR sensors and switches
    Extended self-diagnostics and detection of cable fault

    • Suitable for use with intrinsically-safe pulse meters and nozzle switches


        Customers also purchased

        • GO Industrial Intrinsically Safe Barrier 9202B1A barrier datasheet IECEx Certificate of Conformity
        • GO Industrial Intrinsically Safe Barrier 9202B1A barrier datasheet
        • GO Industrial Intrinsically Safe Barrier 9202B1A barrier manual
        • Can be mounted in the safe area or in zone 2 / Cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Div. 1, Gr. A-G
        • Designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508
        • Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail
        • Front LED indicates operation status and malfunction
        • 2.6 kVac galvanic isolation between input, output and supply
        • Can be supplied separately or installed on power rail, PR type 9400
        • DIN rail mounting
        View full details