Will it pump it?

GO x Small Hire

Will it pump it?

Check the coating, hose and film build against your two Graco units. Then choose a tip.

Built by GO Industrial for the Small Hire fleet

GO x Small Hire

Will it pump it?

Pick the coating and see straight away whether the Ultra 390 PC or the Ultra Max II 650 PC Pro will spray it, and which tip to fit.

Visit Small Hire ↗

Water based coatings only on these corded units. Results are calculated starting points, so test spray and check the wet film before starting the job.

I'm ready to put in more detail

Fan width is nominal at about 300 mm from the surface. The model uses the midpoint of the nominal 2 inch fan band, so a 10 to 12 inch pattern is modelled at 11 inches. Check the actual pattern and overlap on your roof profile.

Hose and viscosity inputs

Roof rise defaults to 6 m for a two storey roof; other categories default to zero. Change it to the actual height. Hose IDs are Graco nominal bores. The calculation also allows 1 m of equivalent 1/4 inch hose for the gun and swivel, a GO estimate.

Printed high-shear / ICI viscosity takes priority for hose loss, then your high-shear measurement, then the labelled high-shear category default. Low-shear and cup readings are used only for intake. Paint shear thinning means a low-shear value can greatly overstate hose loss. KU, Ford 3/4 and Zahn 1 to 5 interpolate the Graco Rev K comparison table at SG 1, then multiply by your measured or sourced SG. The suspect 17 P KU row is excluded. No extrapolation. KU and cup readings cannot be high-shear measurements.

What the data sheet says
Not in the list? Upload or paste the TDS numbers

Enter per-coat figures below. You can also paste labelled numbers or upload a small text file. No file leaves your device. Read PDF data sheets yourself and copy the figures here.

Use coverage per coat or dry film plus volume solids. Leave unknown figures blank. No thinning is applied.

How the estimate works

Wet film = dry film ÷ volume solids, or 1000 ÷ coverage in m²/L. The target sweep speed is 0.6 to 1.0 m/s, a GO field starting assumption. Transfer efficiency 65% and overlap 50% are uncalibrated. The model checks the whole printed film range.

Required flow follows the wet film target, fan width and sweep speed. Graco’s water tip chart is corrected by √(tip pressure / (2000 × SG)), following Rev K cell G10. The old paint factor is removed. High-shear defaults are 20 / 60 / 120 / 250 cP with starting atomising pressures 1200 / 1600 / 2200 / 2600 psi. These are GO assumptions; printed pressure takes priority.

Available flow is the smaller of rated flow and 0.7 × motor HP × 1714 × 3.7854 ÷ pump pressure. Efficiency 70% is assumed. This is a derived constant-power envelope, not a Graco pump curve. The 390 PC uses 0.625 HP and the 650 PC Pro 1.8 HP. Confirm the physical unit and voltage.

Pump pressure includes tip pressure, Darcy-Weisbach hose loss and vertical rise. Friction is 64/Re below Re 2000, otherwise Colebrook with 0.000015 ft roughness. Transition results need a flow test. SG affects hose loss, rise and tip flow. Source: Graco Pressure Loss Calculation, Rev K (spreadsheet supplied by Graco to GO), cells E40 to E50, F20, F21 and G10. Roughness is a workbook assumption, not a measured hose property.

Intake loss is checked at twice discharge flow and must stay under 10 psi, using low-shear viscosity. Both fleet units currently have unscored intake checks because suction tube ID and length are not both sourced. No viscosity class alone gives a No. A viscosity-bound failure asks for a flow test. “Small jobs, slower” means pressure, power and tip checks pass but the target film needs a sweep below 0.6 m/s. Test pattern quality, draw behaviour and wet film before use.

Hose dimensions: Graco ANZ product guide 3C0005ENAP, PDF page 16. Conversions: Graco Rev K, Viscosity tab, rows 7 to 63. Both sources are held by GO.

A few checks

Before you start

Does “Yes” mean the setup has been tested?

No. It means the calculated tip demand fits the unit ratings under the assumptions shown. Confirm the coating maker’s instructions, test the pattern and measure wet film before the job.

Can I use a solvent-based roof paint?

This finder excludes flammable and solvent-based materials on these corded units. Read the coating SDS and exact unit manual. Contact GO if compatibility is unclear.

Should I thin the coating to help the smaller unit?

Only when the coating maker expressly permits it. This finder models unthinned coating. A smaller tip or added water must not be used to bypass the maker’s instructions.