FOZMULA Fuel Level Sensor 4-20MA
- Found a better deal? Message us to price match.
Same-day dispatch
In-stock orders by 2pm AEST
Australia-wide delivery
Direct to your job from Brisbane
Authorised service
In-house warranty + repairs
Trade pricing for all
No trade-only accounts
The Model T/LL352 series is a range of highly advanced sensors for continuously measuring the contents of a fuel tank. Its unique feature is that it re-calibrates itself when a liquid with a different dielectric constant is used. For example, if it is used in a tank of conventional diesel, the user can refill with bio-diesel and the sensor will correct the output level automatically.
Options include a level alarm point set at any point along the stem to be either high or low level, and any suitable receptacle or cable requirement specified by the user. The sensor is suitable for use with diesel, petrol, water or lubricants.
Included accessories
Specifications
| Probe Length | Min 200mm, Max 2000mm (Min 7.9", Max 78.7") |
|---|---|
| Liquid Types | Liquids compatible with construction materials, typically diesel, kerosene, petrol and water |
| Supply Voltage | 9-32 VDC with 80V over voltage protection |
| Supply Current | 15mA @ 12Vdc plus output load |
| Connections | 500mm long 18AWG XPE flying leads, misconnection protection provided |
| Accuracy | ±2.0% of depth @ 20°C (+68°F) |
| Resistive Output | Any values between 3-500Ω or 500-3Ω |
| Current Output | 0-20mA, 4-20mA |
| Voltage Output | 0-5V/5-0V (12VDC system) or 0-10V/10-0V (24VDC system) |
| Housing | Die cast aluminium |
| Internal Sensor | Aluminium |
| Sensor Tube | Anodised aluminium |
| Wetted Seals | PTFE, polypropylene and nitrile |
| Internal Insulators | PTFE |
| Operating Temperature | -40°C to +85°C (-40°F to +185°F) |
| Storage Temperature | -40°C to +105°C (-40°F to +221°F) |
| Weight | 300g (10 oz) for a 1M long unit |
| Sealing | IP67 |
| Max Tank Pressure | 10 psi (0.75 bar) |
| EMC | Type approval in accordance with EN ISO 13766:2006 |
| Vibration | BS EN 60068-2-64:1993, IEC 60068-2-6 |
| Alarm Option | One position at high or low level; high level switches to ground above level, low level switches to ground below level; max load 100mA |
| Connection Option | Any suitable customer specified receptacle can be fitted |
Data Sheet
Manual
Shipping & Returns
Same-day dispatch from one of our national warehouses on in-stock orders placed before 2pm AEST.
30-day returns on unopened, stocked items — customer pays return freight. Non-stocked / special-order items are subject to a 50% restocking fee.
Need help speccing your kit?
Talk to a real specialist on our team. We'll match the right unit to your daily volume and the materials you spray most.